Oxidised bitumen is made by blowing air through hot bitumen. It is harder and less temperature-sensitive than paving bitumen.

← Todos los productosTambién llamado: Blown bitumen, Industrial bitumen, 85/25, 115/15, Roofing bitumen

  • Punto de inflamaciónTypically above 240 C (varies by grade)
  • Densidad1020 to 1060 kg/m³
  • ViscosidadSoftening point 85 to 115 C
  • Azufre1 to 4%
  • PeligroUN3257 for hot bitumen shipped as an elevated temperature liquid, Class 9 (elevated temperature liquid, n.o.s., at or above 100 C and below its flash point)
Color típico, vidrio de laboratorio
Muestra de Oxidised Bitumen (Blown Bitumen) en un vaso de laboratorio, con su color típico
Una muestra de Oxidised Bitumen (Blown Bitumen) en vidrio de laboratorio sobre un fondo oscuro de estudio, para apreciar bien el color.
Fotografía de referencia
Cómo se almacena y se mueve Oxidised Bitumen (Blown Bitumen) en la práctica.

Créditos de las imágenes Las muestras en vidrio de laboratorio se elaboran a partir de fotos de referencia de Wikimedia Commons de Chemik10 (CC BY-SA 2.5) y una foto de muestra de petróleo CC0.

Agite el líquido para sentir su espesor

Mueva el ratón o un dedo sobre el líquido. Mantenga pulsado y arrastre para agitar con más fuerza. Teclado: las flechas agitan, la barra espaciadora sacude.

Semisólido
El color corresponde al color típico de Oxidised Bitumen (Blown Bitumen).
Fino y sueltoEspeso y pesado

Semisólido Semisólido a temperatura normal. Solo se arrastra y hay que calentarlo para bombearlo.

Viscosidad típica según los datosSoftening point 85 to 115 C

Velocidad de agitación
0 px/s
Movimiento del líquido
0%
Se calma tras
-
Superficie
Quieto

La clase es solo una guía de sensación. La viscosidad indicada es la de los datos de la especificación.

Aspecto

Black, hard

Dónde se utiliza

  • Roofing
  • Waterproofing
  • Pipe coating
  • Sealants

Manipulación y seguridad

  • Store in insulated, heated tanks at 150 to 180 C; do not hold above 200 C for long because it ages and can foam if water is present. Avoid water contact (violent boiling). Sample with a heated sampler per ASTM D140 or EN 58 and test penetration, softening point and flash point. Trucks and ships need heating coils and loading arms with steam or thermal oil tracing.
  • Typically stored and moved at about 150 C (Wikipedia). Hot bitumen causes severe burns, and fumes can contain H2S and polycyclic aromatics. Check the local ADR/IMDG classification, which depends on the product and temperature.

Propiedades típicas

Aspecto
Black, hard
Densidad a 15 °C
1020 to 1060 kg/m³
Punto de inflamación
Typically above 240 C (varies by grade)
Viscosidad
Softening point 85 to 115 C
Punto de fluidez
Not applicable
Azufre típico
1 to 4%

◉What it is

Blown bitumen is partly oxidised with air at high temperature after distillation, making it harder (Wikipedia). Grades such as 85/25 and 115/15 are named by softening point and penetration. It is used for roofing felts, waterproofing, pipe coating, and as a sealant. It is less suitable for roads because it is brittle at low temperature.

⬡What it is made of

Asphaltene-rich bitumen.

⚛La química

Oxygen causes dehydrogenation and linking of molecules, raising asphaltene content and softening point.

⚙How it is made

Bitumen is heated to 230 to 280 C in a blowing tower and air is bubbled through for hours.

▶How it works

Lower penetration and higher softening point give resistance to flow at high temperature.

▣Storage, loading and inspection

Store in insulated, heated tanks at 150 to 180 C; do not hold above 200 C for long because it ages and can foam if water is present. Avoid water contact (violent boiling). Sample with a heated sampler per ASTM D140 or EN 58 and test penetration, softening point and flash point. Trucks and ships need heating coils and loading arms with steam or thermal oil tracing.

★Why it matters in the Gulf

Oxidised grades are used for roofing and pipe coating. Gulf production and export details are not stated.

Moléculas clave

Normas y especificaciones

EN 13304European framework specification for oxidised bitumens.
ASTM D312Asphalt used in roofing.
IS 702Indian standard for industrial bitumen.

Peligros

UN3257 for hot bitumen shipped as an elevated temperature liquidClase Class 9 (elevated temperature liquid, n.o.s., at or above 100 C and below its flash point)

Typically stored and moved at about 150 C (Wikipedia). Hot bitumen causes severe burns, and fumes can contain H2S and polycyclic aromatics. Check the local ADR/IMDG classification, which depends on the product and temperature.

Cómo se comercializa

Units

Metric tonnes; bags; drums

Benchmarks

Contract

Typical cargo

Drums, bags, bulk

Incoterms

FOB, CIF

Notes

Specialty.

Refinerías que lo producen: nuestras sugerencias

54 refinerías de la lista producen este producto, 17 de ellas en el Golfo, Irán e Irak. Ordenamos primero las plantas del Golfo, después las que están en operación y luego por capacidad.

Ver los 54 en el mapa

Terminales que lo manipulan

¿Sabía que…?

💡 Blown bitumen is partly oxidised with air at high temperature, which makes it harder (Wikipedia).

💡 Roofing membranes rely on it.

Póngase a prueba sobre Oxidised Bitumen (Blown Bitumen)

Pregunta 1 de 3 · Puntuación 0 · Racha 0

How is oxidised bitumen made?

Más de este grupo

Fuentes

Redactado con palabras propias de PST a partir de las fuentes anteriores. Fiabilidad de los datos: medium. Los valores típicos varían según el origen y el contrato, por lo que debe leer siempre la especificación de su propio contrato.