Перейти к содержимому

Bitumen and solids

Oxidised Bitumen (Blown Bitumen)

Oxidised bitumen is made by blowing air through hot bitumen. It is harder and less temperature-sensitive than paving bitumen.

← Все продуктыДругие названия: Blown bitumen, Industrial bitumen, 85/25, 115/15, Roofing bitumen

  • Температура вспышкиTypically above 240 C (varies by grade)
  • Плотность1020 to 1060 kg/m³
  • ВязкостьSoftening point 85 to 115 C
  • Сера1 to 4%
  • ОпасностьUN3257 for hot bitumen shipped as an elevated temperature liquid, Class 9 (elevated temperature liquid, n.o.s., at or above 100 C and below its flash point)
Типичный цвет, лабораторная посуда
Проба в лабораторном стекле, типичный цвет: Oxidised Bitumen (Blown Bitumen)
Образец Oxidised Bitumen (Blown Bitumen) в лабораторной стеклянной таре на тёмном студийном фоне, чтобы цвет было легко оценить.
Эталонная фотография
Как Oxidised Bitumen (Blown Bitumen) хранят и перевозят на практике.

Авторство изображений Образцы в лабораторной посуде созданы по эталонным фотографиям с Wikimedia Commons, автор: Chemik10 (CC BY-SA 2.5) и фото образца нефти с лицензией CC0.

Помешайте жидкость, чтобы почувствовать её густоту

Проведите мышью или пальцем по жидкости. Нажмите и тяните, чтобы помешать сильнее. Клавиатура: стрелки перемешивают, пробел встряхивает.

Полутвёрдый
Цвет соответствует типичному цвету Oxidised Bitumen (Blown Bitumen).
Жидкая и подвижнаяГустая и тяжёлая

Полутвёрдый При обычной температуре полутвёрдый. Лишь медленно ползёт, для перекачки его нужно нагревать.

Типичная вязкость по даннымSoftening point 85 to 115 C

Скорость перемешивания
0 px/с
Движение жидкости
0%
Успокоилась через
-
Поверхность
Покой

Класс служит ориентиром для ощущения. Показанное значение вязкости взято из данных спецификации.

Внешний вид

Black, hard

Где применяется

  • Roofing
  • Waterproofing
  • Pipe coating
  • Sealants

Обращение и безопасность

  • Store in insulated, heated tanks at 150 to 180 C; do not hold above 200 C for long because it ages and can foam if water is present. Avoid water contact (violent boiling). Sample with a heated sampler per ASTM D140 or EN 58 and test penetration, softening point and flash point. Trucks and ships need heating coils and loading arms with steam or thermal oil tracing.
  • Typically stored and moved at about 150 C (Wikipedia). Hot bitumen causes severe burns, and fumes can contain H2S and polycyclic aromatics. Check the local ADR/IMDG classification, which depends on the product and temperature.

Типичные свойства

Внешний вид
Black, hard
Плотность при 15 °C
1020 to 1060 kg/m³
Температура вспышки
Typically above 240 C (varies by grade)
Вязкость
Softening point 85 to 115 C
Температура застывания
Not applicable
Типичное содержание серы
1 to 4%

◉What it is

Blown bitumen is partly oxidised with air at high temperature after distillation, making it harder (Wikipedia). Grades such as 85/25 and 115/15 are named by softening point and penetration. It is used for roofing felts, waterproofing, pipe coating, and as a sealant. It is less suitable for roads because it is brittle at low temperature.

⬡What it is made of

Asphaltene-rich bitumen.

⚛Химия

Oxygen causes dehydrogenation and linking of molecules, raising asphaltene content and softening point.

⚙How it is made

Bitumen is heated to 230 to 280 C in a blowing tower and air is bubbled through for hours.

▶How it works

Lower penetration and higher softening point give resistance to flow at high temperature.

▣Storage, loading and inspection

Store in insulated, heated tanks at 150 to 180 C; do not hold above 200 C for long because it ages and can foam if water is present. Avoid water contact (violent boiling). Sample with a heated sampler per ASTM D140 or EN 58 and test penetration, softening point and flash point. Trucks and ships need heating coils and loading arms with steam or thermal oil tracing.

★Why it matters in the Gulf

Oxidised grades are used for roofing and pipe coating. Gulf production and export details are not stated.

Ключевые молекулы

Стандарты и спецификации

EN 13304European framework specification for oxidised bitumens.
ASTM D312Asphalt used in roofing.
IS 702Indian standard for industrial bitumen.

Опасности

UN3257 for hot bitumen shipped as an elevated temperature liquidКласс Class 9 (elevated temperature liquid, n.o.s., at or above 100 C and below its flash point)

Typically stored and moved at about 150 C (Wikipedia). Hot bitumen causes severe burns, and fumes can contain H2S and polycyclic aromatics. Check the local ADR/IMDG classification, which depends on the product and temperature.

Как им торгуют

Units

Metric tonnes; bags; drums

Benchmarks

Contract

Typical cargo

Drums, bags, bulk

Incoterms

FOB, CIF

Notes

Specialty.

НПЗ, которые его производят: наши рекомендации

НПЗ в списке, производящих этот продукт: 54, из них в странах Персидского залива, Иране и Ираке: 17. Сначала идут заводы Персидского залива, затем действующие, затем по мощности.

Показать все (54) на карте

Терминалы, которые с ним работают

Знаете ли вы

💡 Blown bitumen is partly oxidised with air at high temperature, which makes it harder (Wikipedia).

💡 Roofing membranes rely on it.

Проверьте себя: Oxidised Bitumen (Blown Bitumen)

Вопрос 1 из 3 · Счёт 0 · Серия 0

How is oxidised bitumen made?

Ещё в этой группе

Источники

Написано собственными словами PST по источникам выше. Достоверность данных: medium. Типичные значения зависят от происхождения и контракта, поэтому всегда читайте спецификацию в своём контракте.