Passare al contenuto

Bitumen and solids

Oxidised Bitumen (Blown Bitumen)

Oxidised bitumen is made by blowing air through hot bitumen. It is harder and less temperature-sensitive than paving bitumen.

← Tutti i prodottiDetto anche: Blown bitumen, Industrial bitumen, 85/25, 115/15, Roofing bitumen

  • Punto di infiammabilitàTypically above 240 C (varies by grade)
  • Densità1020 to 1060 kg/m³
  • ViscositàSoftening point 85 to 115 C
  • Zolfo1 to 4%
  • PericoloUN3257 for hot bitumen shipped as an elevated temperature liquid, Class 9 (elevated temperature liquid, n.o.s., at or above 100 C and below its flash point)
Colore tipico, vetro da laboratorio
Campione in vetro da laboratorio di Oxidised Bitumen (Blown Bitumen), nel suo colore tipico
Un campione di Oxidised Bitumen (Blown Bitumen) in vetro da laboratorio su sfondo scuro da studio, per valutare facilmente il colore.
Fotografia di riferimento
Come Oxidised Bitumen (Blown Bitumen) viene stoccato e movimentato nella pratica.

Crediti delle immagini I campioni in vetro da laboratorio sono realizzati da foto di riferimento su Wikimedia Commons di Chemik10 (CC BY-SA 2.5) e una foto di un campione di petrolio CC0.

Agitate il liquido per sentire quanto è denso

Muovete il mouse o un dito sul liquido. Premete e trascinate per agitare più forte. Tastiera: le frecce agitano, Spazio scuote.

Semisolido
Il colore segue il colore tipico di Oxidised Bitumen (Blown Bitumen).
Fluido e scorrevoleDenso e pesante

Semisolido Semisolido a temperatura normale. Si muove appena e va riscaldato per essere pompato.

Viscosità tipica dai datiSoftening point 85 to 115 C

Velocità di agitazione
0 px/s
Movimento del liquido
0%
Si calma dopo
-
Superficie
Fermo

La classe è solo una guida alla sensazione. Il valore di viscosità mostrato è quello dei dati di specifica.

Aspetto

Black, hard

Dove si usa

  • Roofing
  • Waterproofing
  • Pipe coating
  • Sealants

Manipolazione e sicurezza

  • Store in insulated, heated tanks at 150 to 180 C; do not hold above 200 C for long because it ages and can foam if water is present. Avoid water contact (violent boiling). Sample with a heated sampler per ASTM D140 or EN 58 and test penetration, softening point and flash point. Trucks and ships need heating coils and loading arms with steam or thermal oil tracing.
  • Typically stored and moved at about 150 C (Wikipedia). Hot bitumen causes severe burns, and fumes can contain H2S and polycyclic aromatics. Check the local ADR/IMDG classification, which depends on the product and temperature.

Proprietà tipiche

Aspetto
Black, hard
Densità a 15 °C
1020 to 1060 kg/m³
Punto di infiammabilità
Typically above 240 C (varies by grade)
Viscosità
Softening point 85 to 115 C
Punto di scorrimento
Not applicable
Zolfo tipico
1 to 4%

◉What it is

Blown bitumen is partly oxidised with air at high temperature after distillation, making it harder (Wikipedia). Grades such as 85/25 and 115/15 are named by softening point and penetration. It is used for roofing felts, waterproofing, pipe coating, and as a sealant. It is less suitable for roads because it is brittle at low temperature.

⬡What it is made of

Asphaltene-rich bitumen.

⚛La chimica

Oxygen causes dehydrogenation and linking of molecules, raising asphaltene content and softening point.

⚙How it is made

Bitumen is heated to 230 to 280 C in a blowing tower and air is bubbled through for hours.

▶How it works

Lower penetration and higher softening point give resistance to flow at high temperature.

▣Storage, loading and inspection

Store in insulated, heated tanks at 150 to 180 C; do not hold above 200 C for long because it ages and can foam if water is present. Avoid water contact (violent boiling). Sample with a heated sampler per ASTM D140 or EN 58 and test penetration, softening point and flash point. Trucks and ships need heating coils and loading arms with steam or thermal oil tracing.

★Why it matters in the Gulf

Oxidised grades are used for roofing and pipe coating. Gulf production and export details are not stated.

Molecole chiave

Norme e specifiche

EN 13304European framework specification for oxidised bitumens.
ASTM D312Asphalt used in roofing.
IS 702Indian standard for industrial bitumen.

Pericoli

UN3257 for hot bitumen shipped as an elevated temperature liquidClasse Class 9 (elevated temperature liquid, n.o.s., at or above 100 C and below its flash point)

Typically stored and moved at about 150 C (Wikipedia). Hot bitumen causes severe burns, and fumes can contain H2S and polycyclic aromatics. Check the local ADR/IMDG classification, which depends on the product and temperature.

Come si commercializza

Units

Metric tonnes; bags; drums

Benchmarks

Contract

Typical cargo

Drums, bags, bulk

Incoterms

FOB, CIF

Notes

Specialty.

Raffinerie che lo producono: i nostri suggerimenti

54 raffinerie censite producono questo prodotto, 17 delle quali nel Golfo, in Iran e in Iraq. Diamo la precedenza agli impianti del Golfo, poi a quelli in esercizio, poi a quelli per capacità.

Vedere tutti i 54 sulla mappa

Terminal che lo movimentano

Lo sapeva?

💡 Blown bitumen is partly oxidised with air at high temperature, which makes it harder (Wikipedia).

💡 Roofing membranes rely on it.

Si metta alla prova su Oxidised Bitumen (Blown Bitumen)

Domanda 1 di 3 · Punteggio 0 · Serie 0

How is oxidised bitumen made?

Altro in questo gruppo

Fonti