Skip to content

Heavy fuels

Vacuum Residue

Vacuum residue is the heaviest material left after vacuum distillation. It is the feed for cokers, visbreakers, bitumen and fuel oil blends.

← All productsAlso called: Vacuum bottoms, VR, Vacuum tower bottoms, VTB, Short residue

  • Flash pointAbove 200 C typical
  • Density1000 to 1060 kg/m³
  • ViscosityVery high; over 1,000 mm2/s at 100 C
  • Cold flowOver 30 C (often semi-solid)
  • Sulphur1 to 6%
  • HazardUsually none, Often not dangerous goods; hot product
Typical colour, laboratory glass
Laboratory glass sample of Vacuum Residue, in its typical colour
A sample of Vacuum Residue in laboratory glass on a dark studio background, so the colour is easy to judge.
Colour scale
The colours Vacuum Residue is known to show.

Image credits Laboratory glass samples are made from reference photos on Wikimedia Commons by Chemik10 (CC BY-SA 2.5) and a CC0 petroleum sample photo.

Stir the liquid to feel how thick it is

Move the mouse or a finger across the liquid. Press and drag to stir harder. Keyboard: arrow keys stir, Space shakes.

Semi-solid
Colour follows the typical colour of Vacuum Residue.
Thin and looseThick and heavy

Semi-solid Semi-solid at normal temperature. It only creeps and has to be heated to pump.

Typical viscosity from the dataVery high; over 1,000 mm2/s at 100 C

Stir speed
0 px/s
Liquid movement
0%
Settled after
-
Surface
Still

The class is a guide for feel. The viscosity figure shown is the one in the specification data.

How it looks

Black, tar-like

Where it is used

  • Coker feed
  • Visbreaker feed
  • Bitumen feed
  • Fuel oil blend

Handling and safety

  • Store in heated tanks, typically 40 to 50 C for pumping and 100 to 150 C for centrifuge and injection, with the temperature kept at least 10 C above the pour point and below 20 C under flash point. Avoid overheating that causes coking. Check for incompatibility when mixing batches (ASTM D4740 spot test or D7060). Sampling follows ISO 3170 or ISO 3171 with MARPOL retained sample. Inspect for water, catalytic fines (aluminium plus silicon) and total sediment.
  • Extremely viscous hot product; burns can occur.

Typical properties

Appearance
Black, tar-like
Density at 15 °C
1000 to 1060 kg/m³
Flash point
Above 200 C typical
Viscosity
Very high; over 1,000 mm2/s at 100 C
Pour point
Over 30 C (often semi-solid)
Typical sulphur
1 to 6%

◉What it is

Vacuum residue is the bottom product of a vacuum distillation unit, boiling above about 500 to 550 C. It is almost solid at room temperature and very rich in asphaltenes, metals and sulphur. Refiners upgrade it in delayed cokers, solvent deasphalters or hydrocrackers, or sell it as fuel oil blendstock or bitumen. Wikipedia describes bitumen as the heavy fraction boiling above about 500 C after vacuum distillation.

⬡What it is made of

C40+ hydrocarbons, asphaltenes, resins, heavy metals.

⚛The chemistry

Vacuum residue contains large polycyclic aromatic structures with sulphur, nitrogen and metals (V, Ni). Asphaltenes are insoluble in n-heptane and make the oil stiff.

⚙How it is made

Bottom stream of a vacuum distillation unit operating at 380 to 410 C and under 10 to 40 mmHg.

▶How it works

Heated above 150 C to flow. Upgrading converts it to lighter products.

▣Storage, loading and inspection

Store in heated tanks, typically 40 to 50 C for pumping and 100 to 150 C for centrifuge and injection, with the temperature kept at least 10 C above the pour point and below 20 C under flash point. Avoid overheating that causes coking. Check for incompatibility when mixing batches (ASTM D4740 spot test or D7060). Sampling follows ISO 3170 or ISO 3171 with MARPOL retained sample. Inspect for water, catalytic fines (aluminium plus silicon) and total sediment.

★Why it matters in the Gulf

Gulf refiners process vacuum residue in coking and residue upgrading units. Specific projects are not stated.

Key molecules

Standards and specifications

ASTM D5236Distillation of heavy hydrocarbon mixtures (vacuum potstill)
No standard gradeSold under contract spec

Hazards

Usually noneClass Often not dangerous goods; hot product

Extremely viscous hot product; burns can occur.

How it is traded

Units

Metric tonnes

Benchmarks

Platts assessments for related fuel oil

Typical cargo

Tanker parcels

Incoterms

FOB, CIF

Notes

Quality varies widely.

Refineries that make it: our suggestions

91 listed refineries make this product, 21 of them in the Gulf, Iran and Iraq. We rank Gulf plants first, then operating plants, then by capacity.

See all 91 on the map

Terminals that handle it

Did you know

💡 It can be so thick that it behaves like a solid at room temperature.

💡 Bitumen is the heavy fraction left after vacuum distillation.

Test yourself on Vacuum Residue

Question 1 of 3 · Score 0 · Streak 0

Vacuum residue is the bottom product of which unit?

More in this group

Sources

Written in PST's own words from the sources above. Confidence in the data: medium. Typical values vary by origin and contract, so always read the specification in your own contract.