Bunker Fuel (ISO 8217 Grades)
Bunker fuel is the fuel supplied to ships. ISO 8217 defines distillate grades (DMX, DMA, DMZ, DMB) and residual grades (RMA to RMK).
← Todos los productosTambién llamado: Bunkers, Marine fuel, Marine fuel oil, Ship fuel, Bunker C
- Punto de inflamaciónMin 60 C (43 C for DMX)
- Densidad800 to 1010 kg/m³
- ViscosidadDMX 1.4 to 5.5 mm2/s at 40 C; DMA up to 6.0; DMB up to 11.0; RME up to 180 and RMG up to 380 mm2/s at 50 C; RMK up to 700
- AzufreMax 0.50% globally; 0.10% in ECAs; up to 3.5% with scrubber
- PeligroUsually none. Depending on the description and temperature, shippers may use UN3082 or UN3257., Often not classified as dangerous goods for transport (flash point above 60 C). Class 9 if shipped under UN3082 (environmentally hazardous substance, liquid, n.o.s.) or UN3257 (elevated temperature liquid, n.o.s.). Check the supplier's safety data sheet.


Créditos de las imágenes Las muestras en vidrio de laboratorio se elaboran a partir de fotos de referencia de Wikimedia Commons de Chemik10 (CC BY-SA 2.5) y una foto de muestra de petróleo CC0.
Agite el líquido para sentir su espesor
Mueva el ratón o un dedo sobre el líquido. Mantenga pulsado y arrastre para agitar con más fuerza. Teclado: las flechas agitan, la barra espaciadora sacude.
Muy espeso Muy pesado. Casi no se mueve y vuelve a su sitio despacio.
Viscosidad típica según los datosDMX 1.4 to 5.5 mm2/s at 40 C; DMA up to 6.0; DMB up to 11.0; RME up to 180 and RMG up to 380 mm2/s at 50 C; RMK up to 700
- Velocidad de agitación
- 0 px/s
- Movimiento del líquido
- 0%
- Se calma tras
- -
- Superficie
- Quieto
La clase es solo una guía de sensación. La viscosidad indicada es la de los datos de la especificación.
Aspecto
Clear (distillate) to black (residual)
Dónde se utiliza
- Fuel for merchant ships
- Fuel for navy and ferries
- Power generation
Manipulación y seguridad
- Store in heated tanks, typically 40 to 50 C for pumping and 100 to 150 C for centrifuge and injection, with the temperature kept at least 10 C above the pour point and below 20 C under flash point. Avoid overheating that causes coking. Check for incompatibility when mixing batches (ASTM D4740 spot test or D7060). Sampling follows ISO 3170 or ISO 3171 with MARPOL retained sample. Inspect for water, catalytic fines (aluminium plus silicon) and total sediment.
- Hot product can cause burns. Residual fuels contain polycyclic aromatics and can release hydrogen sulphide in tank headspace. Spills are very damaging to marine life.
Propiedades típicas
- Aspecto
- Clear (distillate) to black (residual)
- Densidad a 15 °C
- 800 to 1010 kg/m³
- Punto de inflamación
- Min 60 C (43 C for DMX)
- Viscosidad
- DMX 1.4 to 5.5 mm2/s at 40 C; DMA up to 6.0; DMB up to 11.0; RME up to 180 and RMG up to 380 mm2/s at 50 C; RMK up to 700
- Punto de fluidez
- Varies by grade
- Azufre típico
- Max 0.50% globally; 0.10% in ECAs; up to 3.5% with scrubber
◉What it is
Bunkers are the fuels ships burn. ISO 8217 divides marine fuels into distillates, which are clear and low viscosity, and residuals, which are heavy blends that need heating. Distillate grades are DMX (emergency, flash point min 43 C), DMA, DMZ and DMB. Residual grades include RMA, RMB, RMD, RME, RMG and RMK, with RMG 380 and RME 180 the most common. Sulphur content is controlled by MARPOL Annex VI: 0.50 percent globally, 0.10 percent in ECAs. Ships buy bunkers at ports and receive a bunker delivery note and a retained sample.
⬡What it is made of
Distillates C10 to C22; residuals C20 to C70+.
⚛La química
See residual and distillate entries. Distillates are paraffin, naphthene and aromatic; residuals include asphaltenes and metals.
⚙How it is made
Distillate bunkers come from the CDU or hydrotreater. Residual bunkers are made by blending vacuum residue or visbroken residue with cutter stock.
▶How it works
Ship engines need fuel at the right viscosity; residual fuel is heated and centrifuged to remove water and catalytic fines. Distillates need no heating.
▣Storage, loading and inspection
Store in heated tanks, typically 40 to 50 C for pumping and 100 to 150 C for centrifuge and injection, with the temperature kept at least 10 C above the pour point and below 20 C under flash point. Avoid overheating that causes coking. Check for incompatibility when mixing batches (ASTM D4740 spot test or D7060). Sampling follows ISO 3170 or ISO 3171 with MARPOL retained sample. Inspect for water, catalytic fines (aluminium plus silicon) and total sediment.
★Why it matters in the Gulf
Fujairah is the main bunker supply point in the Gulf region, just outside the Strait of Hormuz. Fujairah is one of the world's largest bunkering hubs, alongside Singapore and Rotterdam, and lies just outside the Strait of Hormuz on the Gulf of Oman (Wikipedia). Its oil industry zone has about 10 million cubic metres of refined-product storage (Wikipedia, year not given). Current bunker volumes by grade are not stated.
Moléculas clave
Normas y especificaciones
| ISO 8217 | Marine fuel specification: distillates DMX, DMA, DMZ, DMB and residuals RMA to RMK. |
|---|---|
| MARPOL Annex VI | 0.50% global and 0.10% ECA sulphur limits (IMO). |
| ISO 4259 | Use of test method precision in disputes. |
Peligros
Hot product can cause burns. Residual fuels contain polycyclic aromatics and can release hydrogen sulphide in tank headspace. Spills are very damaging to marine life.
Cómo se comercializa
Units
Metric tonnes (bunkers priced per mt); barrels for refinery trade at about 6.4 to 6.6 bbl per mt.
Benchmarks
Platts bunker assessments at Fujairah, Singapore, Rotterdam, Houston, Zhoushan
Typical cargo
Barge or bunker tanker
Incoterms
FOB (load port), CIF or CFR, DAP at bunker port or delivered ex-wharf (barge).
Notes
Singapore is the largest bunkering hub, with 54.9 million tonnes of sales in 2024 (Wikipedia). Fujairah is one of the largest, alongside Rotterdam.
Refinerías que lo producen: nuestras sugerencias
91 refinerías de la lista producen este producto, 21 de ellas en el Golfo, Irán e Irak. Ordenamos primero las plantas del Golfo, después las que están en operación y luego por capacidad.
- 1Ruwais Refinery
United Arab Emirates · 922,000 bpdLargest capacity among Gulf-first matchesGulf locationOperatingDeep conversionAcceso de exportación
- 2Al-Zour Refinery
Kuwait · 615,000 bpdGulf locationOperatingAcceso de exportación
- 3Ras Tanura Refinery
Saudi Arabia · 550,000 bpdGulf locationOperatingDeep conversionAcceso de exportación
- 4SAMREF Yanbu Refinery
Saudi Arabia · 400,000 bpdGulf locationOperatingAcceso de exportación
- 5Petro Rabigh Refinery
Saudi Arabia · 400,000 bpdGulf locationOperatingAcceso de exportación
- 6Abadan Refinery
Iran · 400,000 bpdGulf locationOperatingDeep conversionAcceso de exportación
Terminales que lo manipulan
- Port of Fujairah (anchorage and bunkering)
United Arab Emirates
- Ras Tanura terminal
Saudi Arabia
- Vopak Horizon Fujairah
United Arab Emirates
- Bapco Sitra tank farm and marine terminal
Bahrain
- Yanbu oil terminals (Red Sea)
Saudi Arabia
- VTTI Fujairah
United Arab Emirates
¿Sabía que…?
💡 Singapore sold 54.9 million tonnes of bunker fuel in 2024 (Wikipedia).
💡 DMX, the emergency distillate grade, has the lowest flash point allowed for a marine fuel, 43 C.
Póngase a prueba sobre Bunker Fuel (ISO 8217 Grades)
Which grade is the emergency distillate?
Más de este grupo
- HSFO 3.5% (High Sulphur Fuel Oil)
- VLSFO 0.5% (Very Low Sulphur Fuel Oil)
- ULSFO 0.1% (Ultra Low Sulphur Fuel Oil)
- IFO 380 and IFO 180
- Residual Fuel Oil (RFO / MFO)
- Vacuum Gasoil (VGO)
- Vacuum Residue
- Slurry Oil (Decant Oil)
- Cutter Stock
- Furnace Oil
Fuentes
- Bunker fuel (Wikipedia)
- Fuel oil (Wikipedia)
- IMO: Sulphur oxides (SOx) and particulate matter, Regulation 14
- Port of Singapore (Wikipedia)
- Port of Fujairah (Wikipedia)
- Fujairah (Wikipedia)